SCFH to SCFM Converter
SCFH (Standard Cubic Feet per Hour) and SCFM (Standard Cubic Feet per Minute) both measure gas flow at standard conditions, but use different time bases. Since 1 hour = 60 minutes...
Formula
Source: Engineering Toolbox | Last reviewed: June 7, 2026
Examples
60 SCFH
= 1 SCFM
60 SCFH = 1 SCFM
1000 SCFH
= 16.67 SCFM
60000 SCFH
= 1000 SCFM
Quick Reference Table
| SCFH | SCFM |
|---|---|
| 100 | 1.67 |
| 500 | 8.33 |
| 1000 | 16.67 |
| 10000 | 166.7 |
| 100000 | 1667 |
Where is this used?
Compressor and blower specifications are typically in SCFM.
This converter bridges the gap between billing units and equipment ratings.
In the natural gas industry, custody transfer at city gates, distribution regulators, and large commercial/industrial meters universally uses SCFH or MCF (thousand cubic feet) per hour for billing purposes, while the pipeline itself is operated in psi and the gas composition is tracked by chromatograph (for BTU content).
A 10,000 SCFH commercial customer on a 2 psi service line is consuming about 167 SCFM of gas, and a gas-fired boiler rated for 2,000,000 BTU/hr input with 1,000 BTU/SCF gas needs 2,000 SCFH = 33.3 SCFM — the conversion is needed continuously between the gas billing department (SCFH or MCF) and the equipment operations team (SCFM, BTU/hr, or kW).
In compressed air systems, total plant air consumption is frequently tracked in SCFH (a 100 hp compressor running near full load delivers about 40,000 SCFH or 667 SCFM at 100 psig) while individual pneumatic tools and equipment are specified in SCFM (a 1 hp grinder might use 30 SCFM, an impact wrench 5 SCFM) — the SCFH-to-SCFM conversion is required to reconcile aggregate plant consumption with the sum of individual tool draws.
Laboratory and process gas systems use SCFH for gas cylinder regulator flowmeters (rotameters) — a typical nitrogen regulator rotameter is calibrated 0–100 SCFH, while the equipment being fed (a glove box, a reactor purge, a spectrometer make-up gas) may be specified in sccm, slpm, or SCFM depending on the OEM.
The conversion chain SCFH → SCFM → slpm → sccm is required when integrating heterogeneous gas flow specifications.
Semiconductor fabrication facilities track bulk specialty gas (nitrogen, argon, helium, hydrogen) consumption in SCFH for purchasing and inventory, while the process tools (etchers, CVD reactors, ion implanters) specify gas flow in sccm or slpm — a 500 sccm N₂ process gas flow in a CVD tool equals 1.06 SCFH.
Medical gas pipeline systems in hospitals deliver oxygen, medical air, nitrous oxide, and vacuum through AGA-standard quick-connect fittings, with the central supply systems sized in SCFH (a typical hospital O₂ system supplies 5,000–20,000 SCFH peak) while the bedside flowmeters read in L/min, requiring the SCFH-to-L/min conversion at the patient interface.
Frequently Asked Questions
What standard conditions does SCFH use?
SCFH uses the same standard conditions as SCFM — typically 68°F (20°C) and 14.696 psia (1 atm). Both are normalized to standard reference conditions per CAGI/ISO standards.
How do I convert SCFM to SCFH?
Multiply SCFM by 60. For example, 100 SCFM = 6,000 SCFH.
Is SCFH the same as CFH?
No. CFH (Cubic Feet per Hour) is actual volumetric flow at site conditions. SCFH is corrected to standard conditions, similar to the SCFM vs ACFM distinction.