GPM to LPM Converter
1 US gallon = 3.785411784 L exactly (since 1 US gal = 231 in³ and 1 in = 0.0254 m exactly per the 1959 international yard agreement, giving 231 × 0.0254³ = 0.003785411784 m³ =...
Formula
Source: NIST | Last reviewed: June 7, 2026
Examples
1 GPM (US)
= 3.785 L/min
1 US GPM = 3.785 LPM
10 GPM (US)
= 37.85 L/min
100 GPM (US)
= 378.5 L/min
1000 GPM (US)
= 3785 L/min
Quick Reference Table
| GPM | LPM |
|---|---|
| 1 | 3.79 |
| 5 | 18.93 |
| 10 | 37.85 |
| 20 | 75.71 |
| 50 | 189.27 |
| 100 | 378.54 |
Where is this used?
In water treatment plant design, US municipal plants typically have all process flow rates in MGD and GPM (a 5 MGD plant has an average flow of 3,472 GPM = 13,144 L/min), but the equipment specification may include European pumps (Grundfos, KSB, Wilo, Sulzer) whose published curves are in m³/h, requiring conversion at the equipment selection boundary.
Chemical feed systems for chlorine, sodium hypochlorite, fluoride, coagulants, and pH adjustment chemicals are universally rated in mL/min or L/h in their OEM datasheets (Pulsafeeder, Prominent, LMI), while the carrier water stream in the US plant is documented in GPM — the chemical dose calculation (typically expressed as mg/L or ppm) requires consistent units throughout, making this conversion routine for water utility engineers.
Cooling tower makeup and bleed flows per CTI (Cooling Technology Institute) standards are in GPM, while the European equivalent cooling tower datasheets (BAC, EVAPCO, Hamon) quote in m³/h — a 1,000-ton cooling tower with 3 cycles of concentration has about 240 GPM (908 L/min) of bleed-off that must be communicated in both units when global engineering teams review the same system.
Boiler feedwater and condensate return systems are universally in GPM in US practice (a 200-hp firetube boiler operating at 80% efficiency needs about 720 GPM of feedwater at 212°F), but European boiler OEM datasheets (Viessmann, Bosch Thermotechnology, Hoval) specify in L/h or m³/h, requiring conversion when integrating with US-side steam distribution systems.
Hydraulic oil flow rates for industrial hydraulic systems are typically in GPM in US equipment (a 50 GPM hydraulic power unit is a small industrial size, 200 GPM is large machinery) but in L/min in European OEM literature (the same 50 GPM = 189 L/min).
Reverse-osmosis system designs from Toray, Hydranautics, or LG Chem are tested and rated in GPM of permeate (a single 8-inch RO element produces about 0.25 GPM at standard conditions, and a 4-element pressure vessel produces 1 GPM = 3.785 L/min) but the high-pressure feed pump from a European OEM (Danfoss, Grundfos) is specified in m³/h.
Fire protection system flow rates per NFPA 13, 14, and 20 are universally in GPM (a 500 GPM fire pump is a small commercial size, 1500–2000 GPM is a typical high-rise), but the European EN 12845 standard uses L/min and m³/h — a US-designed sprinkler system being installed in a European building must have all flow rates (demand, hose stream, pump rating) converted for the local fire authority approval.
Petroleum storage and dispensing systems at truck loading racks, terminals, and retail forecourts use GPM in US operations (a loading arm rated 600 GPM for crude or refined products) but L/min or m³/h in international oil trading (the same arm might be specified at 2,270 L/min in a Saudi Aramco or Shell facility).
Industry Standards Referenced
Frequently Asked Questions
Is GPM the same as US GPM and Imperial GPM?
No. GPM in the US almost always means US GPM (1 gal = 3.785 L). UK/imperial GPM is 4.546 L/min, about 20% larger. This converter uses US GPM.
How do I convert LPM to m³/h?
Multiply LPM by 0.06. So 100 LPM = 6 m³/h.
What's the difference between GPM and CFM?
GPM measures liquid volume flow (gallons per minute of water or another fluid). CFM measures gas volume flow (cubic feet per minute of air). They are not directly interchangeable — you'd need density and unit conversions.
Reviewed for accuracy
Reviewed against ANSI/HI 1.3 liquid flow measurement standards · Last reviewed: June 7, 2026
All calculations are for reference only. Always verify with manufacturer data and a qualified engineer for critical applications. Learn about our editorial process.